Adblue (SCR) urea deactivation + Stage 1 VW Touareg 3.0 TDI CVWA 280 hp, 600 Nm.
We performed a Disabling of Adblue (SCR) +Stage 1 280 hp, 600 Nm.
We provide deletion/disable services for:
✅Adblue (SCR) (DEF)
✅EGR (Exhaust Gas Recirculation)
✅DPF (Diesel Particulate Filter)
✅FLAPS (Swirl Flaps)
✅Start Stop (Start-Stop system software disable)
✅Active Grille Shutter (AGS) (Active radiator shutter delete)
Frequent Adblue (SCR) errors:
- 28922 – Reductant
P20E8 00 [237] – Pressure too low - 9656 – Reductant tank heater on
P202B 00 [237] – Short to ground - 22585 – Reductant level sensor
P203B 00 [237] – Invalid signal - 21378 – Reductant dosing module
P20FE 00 [101] – Malfunction - 11393 – Reductant level sensor
P204B 00 [096] – Invalid signal - 14416 – Heating system output stage reducing agent
P20B7 00 [175] – short to ground - 9655 – Reductant tank heater on
P202A 00 [237] – open circuit - 16936 – Reductant heating element 2 on
P20BD 00 [032] – open circuit - 9654 – Reductant heating system output stage
P148B 00 [040] – malfunction - 9650 – Reductant heating system output stage 2
P148C 00 [175] – malfunction - 28648 – Specified in ISO document 15031-6
P206B 00 [237] – 2005
P206B – Reductant quality sensor invalid signal - 9617 – Reductant heating element 1 on
P20B9 00 [10101111] – open circuit - 9636 – Reductant purge valve
P20A0 00 [10101111] – open circuit - 9686 – Reductant tank temperature sensor
P205A 00 [10101111] – electrical malfunction - 10098 – Reductant pump 1 control signal supply
P208B 00 [01100101] – invalid signal - 18612 – Reductant
P207F 00 [01100101] – insufficient efficiency - 28416 – Reductant level sensor/Tank temperature
U121D 00 [10101111] – no communication - 9687 – Reductant tank temperature sensor
P205C 00 [10101111] – short to ground - 41157 – Reductant level sensor
P203F 00 [00100111] – weak signal
- 17277 – SCR; NOx Catalyst; Bank 1
P20EE 00 [101] – Efficiency Too Low - 9879 – NOx Sensor 1 Heating Element; Bank 1
P2209 00 [101] – Invalid Signal - 9574 – NOx Sensor 1; Bank 1
P2200 00 [096] – Electrical Malfunction - 9580 – NOx Sensor 1; row 1
P2201 00 [096] – invalid signal - 9690 – NOx sensor
P1032 00 [096] – signal level too high - 28992 – NOX sensor 2
U029E 00 [175] – no communication - 9567 – NOx sensor 2; Row 1
P229F 00 [237] – invalid signal - 9688 – Reductant tank temperature sensor
P205B 00 [109] – invalid signal - 9654 – Reductant heating system output stage
P148B 00 [040] – malfunction - 9650 – Reductant heating system output stage 2
P148C 00 [175] – malfunction - 37062 – Reductant quality control module
U02A2 00 [175] – no communication - 9611 – Reductant injector; Row 1
P2047 00 [039] – Open Circuit - 9561 – NOx Sensor 2; Row 1
P229E 00 [175] – Electrical Malfunction - 9880 – NOx Sensor 2 Heating Element; Row 1
P22A7 00 [172] – invalid signal - 29630 – Reductant flow
P218F 00 [237] – not recognized - 28413 – Reductant level sensor
P203D 00 [036] – short circuit to positive - 9639 – Reductant pump 1 control signal supply
P208A 00 [10101111] – open circuit - 9633 – Reductant level sensor
P203A 00 [10101111] – electrical malfunction - 9684 – Pressure sensor restorer
P204A 00 [10101111] – electrical malfunction